WEIZHI:     home > Product > Radiation heat transfer end > Cold ceiling
Drywall cold ceiling

Klimakontor cold ceiling system uses water as the medium to eliminate the indoor load. The radiation cooling and heating system does not directly act on the human body and the surface of objects through heating or cooling air temperature, which can realize the independent control of indoor temperature and humidity. The cold ceiling system is more close to the heat transfer way that the human body likes (radiation), lower energy consumption can be traded for higher comfort.

Applicable occasions

The government building

The office building

The museum

Hotel/Restaurant

medical institution

The airport

Shopping center

residential

Product advantages

Relatively low initial investment;


Can use high temperature cold source refrigeration and low temperature heat source heating, energy saving effect is remarkable;


Make full use of new and renewable energy sources;


No sense of wind, no noise, no indoor swirling dust, do not occupy the interior space of the room;


The equipment height is low, can be used for low and high floors;


It can be integrated with indoor equipment, chandelier, tuyere, spray equipment, loudspeaker and so on

technical specifications

MODEL

power

specifications

Installation position

GK50WT

Maximum cooling power: 73w/m2

Maximum heating power: 87W /m2

PB plastic hot and cold water pipe

Aluminium thermal conductor

For smooth surface,

Perforated gypsum board ceiling


GKA50WT

Maximum cooling power: 71w/m2

Maximum heating power: 85W /m2

PB plastic hot and cold water pipe

Aluminium thermal conductor

For smooth surface,

Perforated gypsum board ceiling

GKCUWT

Maximum cooling power:93w/m2

Maximum heating power: 102W /m2

Copper hot and cold water pipes

Aluminium thermal conductor

For smooth surface,

Perforated gypsum board ceiling


GKACUWT

Maximum cooling power: 89w/m2

Maximum heating power: 99W /m2


Copper hot and cold water pipes

Aluminium thermal conductor

For smooth surface,

Perforated gypsum board ceiling


  • Cooling and heating radiation ceiling water supply

Klimakontor cooling, heating and radiation system needs high temperature cold water (16 ° C ~18 ° C) in operation. The best water supply method is that the high temperature cold water/heat pump unit generates cold water of 16 ° C ~18 ° C and directly supplies it to the ceiling system. Under this system configuration and operating conditions, the cooling main engine can obtain much higher COP than the traditional main engine, and the entire air-conditioning system can obtain the maximum energy saving. The control system is simple and efficient. In practical engineering application, the cold and heat source main engine should supply cold water to other low temperature terminal, such as fan coil unit, air processor, etc., and there is not always an independent high temperature water source main engine to supply cold and warm radiation system. At this time, low temperature cold water treatment is needed to meet the requirements of the radiation plate water supply. Can use the three-way valve mixed water heating or heat exchanger heating method, the low temperature cold water to meet the requirements. The system diagram is as follows.


  • Install the cold suspended ceiling

The cooling and heating radiant ceiling plate adopts modular structure, which can be easily installed and removed after the installation of the ceiling keel. Between the ceiling plate and the ceiling plate, and between the ceiling plate and the water supply and return main pipe are connected by the plug and pull type quick connection hose, the installation and later maintenance is extremely convenient

ziliaoxiazai
dianjihuoqu 
ksfsxu